Features
- All-metal, buy-it-for-life construction.
- Quietly and efficiently removes dust, smoke, allergens, bacteria, mold, and viruses from the air.
- Uses two standard, low-cost, non-proprietary 20x25x1 MERV 13 furnace filters, available through Digikey or Temu, almost anywhere in the world.
- Low profile- made to look just like a tower PC.
- No app, no cloud, no "smart" anything. Everything can be repaired or replaced for life with just a screwdriver.
- Uses standard, easily replaceable PC hardware: screws, cables, 140 mm fans, grills, etc.
- Color-match any decor: paint, strip, prime, and repaint as many times as you like. Most auto body shops will do it inexpensively.
- Great family STEM project for all ages: just like assembling a PC case, but with no sharp edges.
- 12 V DC input, ultra-low power consumption (14.5 W)- perfect for off-grid and solar applications.
Performance
Independently lab-measured CADR: 222 CFM at 37 dBA* (PDF). One of the best CADR-to-noise ratios of any air purifier available.
When comparing with other purifiers' maximum CADR, check what they deliver below 40 dBA, not at a noise level you'll never actually use. If you want higher CADR (at higher noise and cost, though still quieter and cheaper than most commercial purifiers), swap in Arctic P14 PWM fans for 248 to 299 CFM.
*Specs and CADR depend on configuration; this was measured with the parts list below.
In the box
- Our own custom-made, high-pressure, ultra-quiet 140 mm fans
- Fan and filter grills
- 12 V power supply with a five-meter cable
- PWM speed controller
- Wiring harness and cable-management parts
- Wall/ceiling mount bracket with screws and anchors (VESA mounting holes)
The included dual-voltage power supply is NEMA 1-15P (US two pole), so you may need a plug adapter for your outlet.
You'll need (not included)
- 2 × 3M Filtrete 20"×25"×1" MPR 1900 (MERV 13) filters, or any standard 20x25x1 MERV 13 furnace filter
Mounting
Wall/Ceiling Mount
High-CADR, low-noise air purifiers like the Tempest Pro require a large filter surface area and so have a relatively large enclosure. Floor space is often at a premium, or you may just want to keep the Tempest Pro out of reach. The included metal bracket, screws, and anchors make wall and ceiling mounting a breeze, and filters can still be swapped easily without removing the unit from its mounting point.
The Tempest Pro wall/ceiling mount installs easily, exactly like a TV wall mount:

Worried that placement will reduce effectiveness? Our computational fluid dynamics (CFD) modeling shows room placement makes only a negligible difference:
VESA Mount
The Tempest Pro's wall/ceiling bracket has VESA mounting holes, so it attaches to a wide variety of fixtures and mounts.
Up to eight units can be placed back to back on a single Autopole with appropriate hardware (option 1, option 2).
This, combined with the Tempest Pro's high CADR, robust construction, and convenient carrying handle, makes it ideal for use at events and on location.
Specifications
| CADR | 222 CFM at 37 dBA, independently lab-measured (PDF)* |
| Power | 12 V DC input, 14.5 W (dual-voltage power supply with a NEMA 1-15P US plug) |
| Filters | 2 × 20x25x1 MERV 13 (not included) |
| Assembled size | 677 × 515 × 192 mm (26.7 × 20.3 × 7.6 in); 256 mm (10.1 in) deep with the wall mount |
| Shipping size | 720 × 300 × 280 mm (28.3 × 11.8 × 11.0 in) |
| Shipping weight | 8.5 kg (18.7 lb) |
| Mounting | Wall/ceiling bracket included, with VESA mounting holes |
Guides & FAQ
- Nukit Tempest Pro Assembly Step-by-Step Guide (read this first)
- Nukit Tempest Pro Assembly Instructions (printable PDF)
- Nukit Tempest Pro FAQ
Accessories
- The Nukit Tempest Power Loss Alarm. Discourages users from unplugging and disabling your air purifier.
- Nukit CO2 Controller. Turns the Nukit Tempest on and off in response to ventilation/CO2 levels.
Huge thanks to Zack Deis for contributing his design, which we have continued to iterate on.
Air changes & infection-risk drop for your room
CADR 222 CFM · lab measuredEnter your room size to see how many times per hour the Tempest Pro filters all the air in it (ACH), and the estimated drop in airborne infection risk.
Enter your room size
We'll show how well the Tempest Pro covers this space.
ACH = clean air delivered per hour ÷ room volume, based on the independently lab-measured 222 CFM CADR @ 37 dBA. The U.S. CDC recommends targeting at least 5 air changes per hour in occupied indoor spaces,1 while Harvard's Healthy Buildings program advises 4–6 ACH for classrooms and shared rooms.2 The infection-risk figure is a relative estimate for long-range, well-mixed airborne transmission only (Wells–Riley / Rudnick & Milton3); it is not an absolute chance of infection and ignores close-range exposure. Real-world results vary with ceiling height, layout, and door/window sealing.
- CDC / NIOSH, “Ventilation in Buildings: Aim for 5 air changes per hour.”
- Harvard T.H. Chan School of Public Health, Healthy Buildings Program — schools ventilation guidance (4–6 ACH).
- Rudnick, S.N. & Milton, D.K. (2003), Risk of indoor airborne infection transmission estimated from carbon dioxide concentration, Indoor Air.